Parameters with AQUAREAD™ Ltd.
Aquaread™ offers a large range of electrodes
Aquaprobes are supplied with a standard set of parameters and customisable ports to take ISE and optical electrodes.
Standard Parameters
| Please click the Want To Know More button next of each parameter for extra details on the sensor and why it is used in water monitoring. | |||
| Optical Dissolved Oxygen | Want to know more? |
Range | 0 500.0% / 0 50.00 mg/L |
| Resolution | 0.1% / 0.01mg/L | ||
| Accuracy | 0 - 200%: ± 1% of reading. 200% - 500%: ± 10% | ||
| Conductivity (EC) | Want to know more? |
Range | 0 200 mS/cm (0 - 200,000 µS/cm) |
| Resolution | 3 Auto-range scales: 0 9999 µS/cm, 10.00 99.99 mS/cm, 100.0 200.0mS/cm | ||
| Accuracy | ± 1% of reading or ± 1µS/cm if greater | ||
| TDS* | Want to know more? |
Range | 0 100,000 mg/L (ppm) |
| Resolution | 2 Auto-range scales: 0 9999mg/L, 10.00 100.00g/L | ||
| Accuracy | ± 1% of reading or ± 1mg/L if greater | ||
| Resistivity* | Want to know more? |
Range | 5 Ωcm 1 MΩcm |
| Resolution | 2 Auto-range scales: 5 9999 Ωcm, 10.0 1000.0 KΩcm | ||
| Accuracy | ± 1% of reading or ± 1 Ωcm if greater | ||
| Salinity* | Want to know more? |
Range | 0 70 PSU / 0 70.00 ppt (g/Kg) |
| Resolution | 0.01 PSU / 0.01 ppt | ||
| Accuracy | ± 1% of reading or ± 0.1 unit if greater | ||
| Seawater Specific Gravity* | Want to know more? |
Range | 0 50 st |
| Resolution | 0.1 st | ||
| Accuracy | ± 1.0 st | ||
| pH | Want to know more? |
Range | 0 14 pH / ± 625mV |
| Resolution | 0.01 pH / ± 0.1mV | ||
| Accuracy | ± 0.01 pH / ± 5mV | ||
| ORP | Want to know more? |
Range | ± 2000mV |
| Resolution | 0.1mV | ||
| Accuracy | ± 5mV | ||
| Temperature | Want to know more? |
Range | -5°C +50°C (23°F 122°F) |
| Resolution | 0.1° C/F | ||
| Accuracy | ± 0.5° C | ||
* Readings calculated from EC and temperature values
Optional Parameters
| Depth ** | Want to know more? |
Range | 0 100m (0 330F) |
| Resolution | 0.01m/F | ||
| Accuracy | ± 1% | ||
| **Option on the AP-2000. Comes as standard on the AP-7000 | |||
Ion Specific Electrodes*** | |||
| Please click the Want To Know More button next of each parameter for extra details on the sensor and why it is used in water monitoring. | |||
| Ammonium | Want to know more? |
Range | 0 1,000mg/L (ppm) |
| Resolution | 2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 999.9 mg/L | ||
| Accuracy | ± 10% of reading | ||
| Ammonia | Want to know more? |
Range | 0 1,000mg/L (ppm) |
| Resolution | 2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 999.9 mg/L | ||
| Accuracy | ± 10% of reading | ||
| Chloride | Want to know more? |
Range | 0 1,000mg/L (ppm) |
| Resolution | 2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 999.9 mg/L | ||
| Accuracy | ± 10% of reading | ||
| Flouride | Want to know more? |
Range | 0 1,000mg/L (ppm) |
| Resolution | 2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 999.9 mg/L | ||
| Accuracy | ± 10% of reading | ||
| Nitrate | Want to know more? |
Range | 0 1,000mg/L (ppm) |
| Resolution | 2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 999.9 mg/L | ||
| Accuracy | ± 10% of reading | ||
| Calcium | Want to know more? |
Range | 0 1,000mg/L (ppm) |
| Resolution | 2 Auto-range scales: 0.00 - 99.99 mg/L, 100.0 999.9 mg/L | ||
| Accuracy | ± 10% of reading | ||
| Ammonium electrode required. Readings calculated from Ammonium, pH and temperature electrode values. | |||
Optical Electrodes*** | |||
| Please click the Want To Know More button next of each parameter for extra details on the sensor and why it is used in water monitoring. | |||
| Turbidity | Want to know more? |
Range | 0 3000 NTU |
| Resolution | 2 Auto-range scales: 0.0 99.9 NTU, 100 3000 NTU | ||
| Repeatability | ± 2% of reading | ||
| Chlorophyll | Want to know more? |
Range | 0 500 µg/L (ppb) |
| Resolution | 0.1 µg/L | ||
| Repeatability | ± 2% of reading | ||
| Phycocyanin (Freshwater Blue-Green Algae) | Want to know more? |
Range | 0 300,000 cells/mL |
| Resolution | 1 cell/mL | ||
| Repeatability | ± 2% of reading | ||
| Phycoerythrin (Marine Blue-Green Algae) | Want to know more? |
Range | 0 200,000 cells/mL |
| Resolution | 1 cell/mL | ||
| Repeatability | ± 2% of reading | ||
| Rhodamine WT Dye | Want to know more? |
Range | 0 500 µg/L (ppb) |
| Resolution | 0.1 µg/L | ||
| Repeatability | ± 5% of reading | ||
| Fluorescein Dye | Want to know more? |
Range | 0 500 µg/L (ppb) |
| Resolution | 0.1 µg/L | ||
| Repeatability | ± 5% of reading | ||
| Refined Oil | Want to know more? |
Range | 0 10,000 µg/L (ppb) |
| Resolution | 0.1 µg/L | ||
| Repeatability | ± 2% of reading | ||
***Note
In addition to the standard parameters supplied with the base Aquaprobe, the AP-2000 has 1 ISE port and 1 optical port, the AP-5000 has 4 ports that can take any combination of ISE or optical sensors and the AP-7000 has 6 ports that can also take any combination of ISE or optical sensors.
The accuracy figures quoted above represent the equipment's capability at the calibration points at 25°C. These figures do not take into account errors introduced by variations in the accuracy of calibration solutions and errors beyond the control of the manufacturer that may be introduced by environmental conditions in the field.